The design of solar panel systems with a (lead-acid) buffer battery is
normally such that the battery is charged even when there is not much
sunshine. This means, however, that when there is plenty of sunshine, a
regulator is needed to prevent the battery from being overcharged. Such
controls usually arrange for the superfluous energy to be dissipated in a
shunt resistance or simply for the solar panels to be short-circuited.
It is, of course, an unsatisfactory situation when the energy derived
from a very expensive system can, after all , not be used to the full.
The circuit presented diverts the energy from the solar panel when the
battery is fully charged to another user, for instance, a 12V ice box
with Peltier elements, a pump for drawing water from a rain butt, or a
12V ventilator.
It is, of course, also possible to arrange for a second battery to be charged by the super-fluous energy. In this case, however, care must be taken to ensure that when the second battery is also fully charged , there is also a control to divert the superfluous energy. The shunt resistance needed to dissipate the superfluous energy must be capable of absorbing the total power of the panel, that is, in case of a 100W panel, its rating must be also 100 W. This means a current of some 6–8 A when the operating voltage is 12 V. When the voltage drops below the maximum charging voltage of 14.4V growing to reduced sunshine, the shunt resistance is disconnected by an n-channel power field effect transistor (FET), T1.
It is, of course, also possible to arrange for a second battery to be charged by the super-fluous energy. In this case, however, care must be taken to ensure that when the second battery is also fully charged , there is also a control to divert the superfluous energy. The shunt resistance needed to dissipate the superfluous energy must be capable of absorbing the total power of the panel, that is, in case of a 100W panel, its rating must be also 100 W. This means a current of some 6–8 A when the operating voltage is 12 V. When the voltage drops below the maximum charging voltage of 14.4V growing to reduced sunshine, the shunt resistance is disconnected by an n-channel power field effect transistor (FET), T1.
The disconnect point is not affected by large temperature fluctuations
because of a reference voltage provided by IC1. The necessary comparator
is IC2, which owing to R9 has a small hysteresis voltage of 0.5V.
Capacitor C5 ensures a relatively slow switching process, although the
FET is already reacting slowly owing to C4. The gradual switching
prevents spurious radiation caused by steep edges of the switched
voltage and also limits the starting current of a motor (of a possible
ventilator). Finally, it prevents switching losses in the FET that might
reach 25W, which would m a ke a heat sink unavoidable. Setting up of
the circuit is fairly simple. Start by turning P1 so that its wiper is
connected to R5.
When the battery reaches the voltage at which it will be switched off, that is, 13.8 – 14.4V, adjust P1 slowly until the output of comparator I C2 changes from low to high, which causes the load across T1 to be switched in. Potentiometer P1 is best a 10-turn model. When the control is switched on for the first time, it takes about 2 seconds for the electrolytic capacitors to be charged. During this time, the output of the comparator is high, so that the load across T1 is briefly switched in. In case T1 has to switch in low-resistance loads, the BUZ11 may be replaced by an IRF44, which can handle twice as much power (150 W) and has an on-resistance of only 24 mR. Because of the very high currents if the battery were short-circuited, it is advisable to insert a suitable fuse in the line to the regulator. The circuit draws a current of only 2 mA in the quiescent state and not more than 10 mA when T1 is on.
When the battery reaches the voltage at which it will be switched off, that is, 13.8 – 14.4V, adjust P1 slowly until the output of comparator I C2 changes from low to high, which causes the load across T1 to be switched in. Potentiometer P1 is best a 10-turn model. When the control is switched on for the first time, it takes about 2 seconds for the electrolytic capacitors to be charged. During this time, the output of the comparator is high, so that the load across T1 is briefly switched in. In case T1 has to switch in low-resistance loads, the BUZ11 may be replaced by an IRF44, which can handle twice as much power (150 W) and has an on-resistance of only 24 mR. Because of the very high currents if the battery were short-circuited, it is advisable to insert a suitable fuse in the line to the regulator. The circuit draws a current of only 2 mA in the quiescent state and not more than 10 mA when T1 is on.
Tidak ada komentar:
Posting Komentar